Industrial Axial Fans







Product description:
used in condenser low noise AC axial fan series has excellent performance, with diameter range from φ200 to φ900 mm and maximum air volume up to 24,000m3/h. This series of fans has been market tested over years and we have optimized product structural reliability, materials, and blade design, with the manufacturing process having been also upgraded. This external rotor fan series has a compact structure, operates reliably and is both energy saving and efficient. It is designed with low noise, a long service life, and is easy to install.
Advantages of SPCC blades axial fans:
1, Good cooling effect
2, ventilation time is easy to master, not easy to appear condensation
3, no separate fan, convenient and flexible
4, Low energy consumption per unit, which is particularly important in advocating energy saving
Disadvantages:
1,Due to small air volume, long ventilation time
2, the precipitation effect is not obvious, high water grain should not be ventilated by axial fan.
Type |
Voltage
V |
Frequency
Hz |
Current
A |
Input Power W | Airflow m³/h | Noise dB (A) | AC/EC | |
A2E-200S-92/15 | 220 | 50 | 0.23 | 50 | 890 | 50 | AC | |
60 | 0.31 | 67 | 980 | 51 | ||||
A2D200S- 92/15 | 380 | 50 | 0.1 | 47 | 750 | 50 | AC | |
60 | 0.14 | 55 | 820 | 51 | ||||
A2E-250S-92/25 | 220 | 50 | 0.45 | 95 | 1290 | 55 | AC | |
60 | 0.58 | 125 | 1490 | 56 | ||||
A2D-250S- 92/25 | 380 | 50 | 0.18 | 90 | 1300 | 55 | AC | |
60 | 0.19 | 115 | 1450 | 57 | ||||
A4E-300S-92/35 | 220 | 50 | 0.42 | 85 | 1700 | 56 | AC | |
60 | 0.46 | 100 | 1850 | 50 | ||||
A4D-300S-92/35 | 380 | 50 | 0.24 | 90 | 1700 | 55 | AC | |
60 | 0.25 | 110 | 1800 | 56 | ||||
A4E-315S-92/35 | 220 | 50 | 0.42 | 90 | 1750 | 56 | AC | |
60 | 0.55 | 120 | 1900 | 58 | ||||
A4D-315S-92/35 | 380 | 50 | 0.25 | 90 | 1750 | 55 | AC | |
60 | 0.26 | 120 | 1900 | 56 | ||||
A4E-330S-92/35 | 220 | 50 | 0.52 | 105 | 2000 | 59 | AC | |
60 | 0.62 | 140 | 2100 | 61 | ||||
A4D-330S-92/35 | 380 | 50 | 0.26 | 110 | 2000 | 58 | AC | |
60 | 0.31 | 142 | 2100 | 60 | ||||
A4E-350S-102/47 | 220 | 50 | 0.75 | 166 | 2600 | 66 | AC | |
60 | 1.00 | 242 | 2900 | 67 | ||||
A4D-350S-102/47 | 380 | 50 | 0.42 | 166 | 2600 | 66 | AC | |
60 | 0.46 | 242 | 2900 | 67 | ||||
A4E-400S-102/60 | 220 | 50 | 0.95 | 185 | 3400 | 66 | AC | |
60 | 1.46 | 260 | 3700 | 67 | ||||
A4D-400S-102/60 | 380 | 50 | 0.51 | 185 | 3400 | 66 | AC | |
60 | 0.48 | 245 | 3700 | 67 | ||||
A4E-450S-137/35 | 220 | 50 | 1.7 | 370 | 6300 | 70 | AC | |
60 | 2.0 | 450 | 6500 | 71 | ||||
A4D-450S-137/35 | 380 | 50 | 0.75 | 370 | 6300 | 70 | AC | |
60 | 0.85 | 430 | 6500 | 71 | ||||
A4E-500S-137/42 | 220 | 50 | 2.00 | 410 | 6450 | 70 | AC | |
60 | 2.50 | 490 | 6700 | 71 | ||||
A4D-500S-137/42 | 380 | 50 | 0.95 | 410 | 6500 | 69 | AC | |
60 | 0.90 | 490 | 6700 | 70 | ||||
A4E-550S-137/50 | 220 | 50 | 2.5 | 550 | 7300 | 73 | AC | |
60 | 3.3 | 720 | 8500 | 74 | ||||
A4D-550S-137/50 | 380 | 50 | 1.65 | 600 | 7500 | 73 | AC | |
60 | 1.65 | 850 | 8600 | 74 | ||||
A4E-600S-137/70 | 220 | 50 | 2.9 | 605 | 8300 | 73 | AC | |
60 | 4.2 | 900 | 1000 | 76 | ||||
A4D-600S-137/70 | 380 | 50 | 1.2 | 530 | 7300 | 74 | ||
60 | 1.45 | 800 | 8300 | 76 | ||||
A4D-630S-168/50 | 380 | 50 | 2.1 | 980 | 10300 | 77 | AC | |
60 | 2.8 | 1500 | 15500 | 79 | ||||
A6D-630S-168/80 | 380 | 50 | 3.18 | 1450 | 13000 | 79 | ||
60 | 4.16 | 2180 | 18000 | 82 | ||||
A6D-710S-168/50 | 380 | 50 | 1.7 | 720 | 11500 | 77 | AC | |
60 | 1.95 | 1050 | 14500 | 79 | ||||
A6D-710S-180/75 | 380 | 50 | 1.9 | 1050 | 11000 | 75 | ||
60 | 2.42 | 1250 | 16500 | 77 | ||||
A6D-800S-180/75 | 380 | 50 | △2.85 | 1150 | 12000 | 75 | AC | |
Y1.65 | 920 | 10500 | 72 | |||||
A6D-800S-180/105 | 380 | 50 | △ 3.45 | 1900 | 24500 | 80 | AC | |
Y 2.2 | 1300 | 18500 | 79 | |||||
A6D-910S-180/120 | 380 | 50 | 4 | 2000 | 900 | 79 | AC | |
2.4 | 1300 | 750 | 76 | |||||
A8D-910S-180/120 | 380 | 50 | 2.8 | 1300 | 700 | 78 | AC | |
1.4 | 800 | 600 | 73 |

- *Title
- *Content
- The fan used on the evaporator, the key point of attention.Sep 11,2025Quantify: Don't guess airflow and pressure. Match: Select the fan to operate at its BEP for your specific system curve. Verify: Measure airflow at startup and adjust. This is the single most important commissioning task. Maintain: Keep it clean and balanced. The performance degradation is quadratic with speed reduction due to fouling. Evaluate Lifecycle Cost: The higher efficiency of an ECM motor often justifies its cost through operational energy savings, especially in variable load application
- As an engineer specializing in the fans of the HVAC system. What factors do I need to pay attention to?Sep 4,2025As an engineer specializing in HVAC fans, your focus shifts from purely commercial considerations to the deep technical and application-specific details that ensure optimal system performance, reliability, and efficiency. Here is a comprehensive breakdown of the critical factors you need to engineer and specify.